2×2 magneto-optical switch

2×2 magneto-optical switch

¥0.00
跳至产品信息
2×2 magneto-optical switch

2×2 magneto-optical switch

¥0.00

Product Features
● No moving components
● Fast switching speed
● Extremely stable latching mode
● Low power consumption
● Excellent stability and reliability

Applications
● Passive optical networks
● Optical protection systems
● Measurement systems
● Network monitoring

Technical parameters

Technical parameters

parameter unit 2×2 magneto-optical switch unit
unidirectional Two-way
Wavelength Range nm 1525 ~ 1565 Other bands optional
Insertion Loss dB 0.7 (Typ.); 1.1 (Max) 0.8 (Typ.); 1.2 (Max)
PDL (Polarization Dependent Loss) dB 0.10 (Typ.); 0.20 (Max) 0.10 (Typ.), 0.30 (Max)
Return Loss dB 45 30
Crosstalk dB 40 30
Repeatability dB +/- 0.01
Durability (Lifespan) Cycles > 100 Billions
Switching Speed s Regular (50~200); Ultra-fast (5~20)
Maximum Optical Power mW 500
Storage Temperature °C -40 ~ 85
Operating Temperature -5 ~ 70
Dimension (L × W × H) mm 63 × 8 × 7

Electronic control parameters

Parameter Specification Unit
Regular Ultra-fast
Switching Speed 50~200 5~20 μs
Switching Voltage (VCC) 3 (+/-5%) 5.0~6.0 V
Switching Current < 200 < 500 mA
Pulse Width (typical) 1000 20 μs
Claim Frequency < 800 < 3000 Hz

Driver pin definition
unidirectional

Switching State Pin1 Pin2 The Optical Output Port
State “0” 1 (Voltage = VCC) 0(Voltage = IN1→OUT 1; IN2→OUT 2
GND)
State “1” 0 (Voltage = GND) 1(Voltage = VCC) IN1→OUT 2; IN2→OUT 1

 Two-way

Switching State Pin1 Pin2 The Optical Output Port
State “0” 1 (Voltage = VCC) 0 (Voltage = GND) IN1↔OUT 1; IN2↔OUT 2
State “1” 0 (Voltage = GND) 1(Voltage = VCC) IN1↔OUT 2; IN2↔OUT 1

Power and wavelength testing

Test the signal transmission strength and wavelength, ensure the signal decoding capability of the receiver, and maintain consistency in wavelength from the transmitter to the receiver.

Traffic Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.