1*N optical switch module

1*N optical switch module

¥0.00
跳至产品信息
1*N optical switch module

1*N optical switch module

¥0.00

Product Features
● Low insertion loss
● Wide wavelength range
● Low crosstalk
● High stability and reliability
● Parallel interface (TTL level) control
● Modular design

Applications
● Laboratory R&D
● System Monitoring
● OADM Configuration
● Metropolitan Area Networks
● Multi-channel Optical Monitoring
● Fiber Optic Sensing
● Remote Fiber Optics
● Monitoring Systems

Technical parameters

model 1*N optical switch module
wavelength range nm 800~1100 (MM) 1400~1700 (MM) 1250~1650 (SM)
Test wavelength nm 850/980 1550 1310/1490/1550/1625
Insertion loss dB Typ: 0.6 Max: 1.0 Typ: 0.6 Max: 1.0 Typ: 0.8 Max: 1.3
Return loss dB SM≥50, MM≥30
Channel crosstalk dB SM≥55, MM≥50
Polarization-dependent loss dB ≤0.05
Wavelength-dependent loss dB ≤0.25
Temperature-dependent loss dB ≤0.25
Repeatability dB ≤±0.02
Operating voltage V +5 (DC)
Service life times ≥107
Switching time (ms) ≤10 (adjacent channel handover)
Transmitted optical power mW ≤500
Operating temperature (°C) -20~+70
Storage temperature ℃ -40~+85

Pin Definitions

DB9 (TTL level):

Pin number Signal direction and type   (In/Out/Power) Pin Definitions Function Description
1 In D0 Data bits. D3~D0 are binary numbers, with D3 being the high-order bit and D0 the low-order bit. These 4 data bits can control up to 16 optical switches. Where 0000b = channel 1; 1111b = channel 16. Data is sent according to the actual number of channels of the optical switch during use.
2 In D1
3 In D2
4 In D3
5 In /Reset A low level resets the channel to channel 0, while a high level indicates that the data bits are valid.
6 Out /Ready Low level indicates readiness for reset or data reception.
7 Out Error A high level indicates a problem with the optical module.
8 Power GND ground wire
9 Power DC 5V DC 5V, 1.0A operating power supply

DB15 (TTL level):

Pin number Signal direction and type   (In/Out/Power) Pin Definitions Function Description
2 In D0 Data bits D5~D0 are binary numbers, with D5 being the high-order bit and D0 the low-order bit. A 6-bit binary number can control up to 64 optical switches. Specifically, 000000b = channel 1; 111111b = channel 64. When using this method, the data sent should be based on the actual number of optical paths of the optical switch.
3 In D1
4 In D2
5 In D3
6 In D4
10 In D5
11 In /Reset Low level resets the system; high level indicates that the data bits are active.
7 Out /Ready Low level indicates readiness for reset or data reception.
8 Out Error A high level indicates that an error has occurred.
15 Power 5V Digital circuit power supply
12 Power 5V Motor power supply
1, 9 Power Ground Public ground wire
13, 14 Not connected

Power and wavelength testing

Test the signal transmission strength and wavelength, ensure the signal decoding capability of the receiver, and maintain consistency in wavelength from the transmitter to the receiver.

Traffic Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.

You may also like