1×2 polarization-maintaining magneto-optical switch

1×2 polarization-maintaining magneto-optical switch

¥0.00
跳至产品信息
1×2 polarization-maintaining magneto-optical switch

1×2 polarization-maintaining magneto-optical switch

¥0.00

Features
● Compact structure
● Fast switching speed (μs level)
● Low insertion loss, high isolation
● High reliability and high stability

Applications
● Sensing
● Optical Protection Systems
● Network Monitoring
● Aerospace Radar

Complies with standards
● Telcordia GR-1221
● Telcordia GR-1073

Technical parameters

parameter unit 1×2 polarization-maintaining magneto-optical switch
Operating wavelength nm 1295~1325, 1520~1580
Test wavelength nm 13,101,550
Insertion loss dB ≤0.8
Extinction ratio dB ≥18
Temperature-related losses dB ≤0.3
Polarization-dependent loss dB ≤0.2
Return loss dB ≥50
Crosstalk dB ≥50 (Dual Stage)
≥25 (Single Stage)
Switching Time μ s ≤50
Pulse width μs ≥200
life Cycles ≥100
Fiber optic model Panda PM Fiber
Operating voltage V 5.0 
Maximum optical power mW ≤500
Operating temperature -5~+70
Storage temperature -40~+85
Package size mm L58.6×W8.4×H8.4(±0.2)
 1. All parameters were tested at room temperature;
 2. All parameters exclude connector insertion loss.

Pin Definitions

type state Optical Path Pin1 Pin2
1×2 in one direction A Pl→P2 GND 5V Pulse
B PI→P3 5V Pulse GND
unidirectional 2×1 A P2→P1 5V Pulse GND
B P3→P1 GND 5V Pulse
1×2 bidirectional A P1→P2 GND 5V Pulse
B P1→P3 5V Pulse GND

 Electrical Specifications

parameter unit Minimum value Typical value Maximum value
Drive voltage V 4.5  5.5 
Drive current mA 110  140  195 
Pulse duration us 200  300  500 

Power and wavelength testing

Test the signal transmission strength and wavelength, ensure the signal decoding capability of the receiver, and maintain consistency in wavelength from the transmitter to the receiver.

Traffic Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.

You may also like